Language:
Undetermined
Pages:
1 Online-Ressource (364 p.)
Series Statement:
Karlsruher Reihe Massivbau, Baustofftechnologie, Materialprüfung
Keywords:
Civil engineering, surveying & building
Abstract:
An innovative strengthening technique for the seismic retrofitting of masonry buildings is the fabric-reinforced cementitious matrix (FRCM). The system presented in this work is EQ-GRID, which consists of a multi-axial hybrid grid made of alkali-resistant glass and polypropylene fibres and a natural hydraulic lime mortar (NHL) as matrix. The results of the performed experimental campaign and the numerical modelling with the Equivalent frame method are presented and discussed in this work
Note:
English
Permalink